| Specifications |
| Function |
Range and Resolution |
Basic Accuracy |
| DC volts |
50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
0.03% |
| AC volts |
0.4 % (True-RMS) |
| DC current |
500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
0.05% |
| AC current |
0.6 % (True-RMS) |
| Temperature (excluding probe) |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
1.0 % |
| Resistance |
50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ,5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
0.05% |
| Capacitance |
1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
1.00% |
| Frequency |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
0.01% |
| Connectivity |
Optional infrared connector via Fluke ir3000 FC |
| |
|
|
| General Specifications |
|
| Maximum voltage between any terminal and earth ground |
1000 V |
|
| Battery type |
6 AA alkaline batteries, NEDA 15A IECLR6 |
|
| Battery life |
100 hours minimum, 200 hours in logging mode |
|
| Temperature |
Operating: -20 °C to 55 °C; Storage: -40 °C to 60 °C |
|
| Relative humidity |
0 to 90 % (0 t 37 °C), 0 to 65 % (37 °C to 45 °C), 0 to 45 % (45 °C to 55 °C) |
|
| Electromagnetic compatibility |
EMC EN61326-1 |
|
| Vibration |
Random vibration per MIL-PRF-28800F Class 2 |
|
| Shock |
1 meter drop per IEC/EN 61010-1 3rd Edition |
|
| Size (HxWxL) |
22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
|
| Weight |
870.9 g (28 oz) |
|
| Multiple on screen displays |
Yes |
|
| True-RMS AC bandwidth |
100 kHz |
|
| dBV/dBm |
Yes |
|
| DC mV resolution |
1 μV |
|
| Megohm range |
Up to 500 MΩ |
|
| Conductance |
50.00 nS |
|
| Continuity beeper |
Yes |
|
| Battery/fuse access |
Yes/Yes |
|
| Elapse time clock |
Yes |
|
| Time of day clock |
Yes |
|
| Min-max-avg |
Yes |
|
| Duty cycle |
Yes |
|
| Pulse width |
Yes |
|
| Isolated optical interface |
Yes |
|
| Auto/touch hold |
Yes |
|
| Reading memory |
Yes |
|
| Log to PC |
Yes |
|
| Interval/event logging |
Yes |
|
| Logging memory |
Up to 15,000 readings |
|
| Wireless connectivity (optional) |
Yes |
|